# SpawnWorker fails against current `yoi-runtime` CLI Date: 2026-07-30 ## Symptom A `SpawnWorker` tool call failed before creating its socket. The child process stderr was: ```text yoi-runtime: unexpected positional argument `worker` Usage: yoi-runtime [OPTIONS] ``` The Worker-management layer appears to invoke the configured Runtime executable with a legacy positional `worker` subcommand, while the current `yoi-runtime` binary starts the Runtime HTTP service directly and no longer accepts that subcommand. ## Impact Read-only review delegation was unavailable during the Workspace credential repair implementation. Work had to continue in the parent Worker without a spawned reviewer. ## Suggested investigation - Check the SpawnWorker process launcher command construction against the current `yoi-runtime` CLI contract. - Ensure runtime executable discovery does not select the server binary when a dedicated Worker child executable/protocol entrypoint is required. - Add an integration test that starts a spawned Worker through the same command used by the Worker-management tool and waits for its socket.